Search results for "Clinical Alarm"

showing 5 items of 5 documents

Topical Issues in Venous Thromboembolism

2010

Despite clear guidelines and the availability of effective treatments, venous thromboembolism (VTE) remains relatively common, particularly in the hospital setting. This paper reviews topical issues in VTE, in terms of treatments, data and guidelines. Existing anticoagulants have several limitations. Bleeding risk is a concern with all anticoagulants. Vitamin K antagonists are the mainstay of oral anticoagulant therapy, but they are limited by the need for frequent monitoring. Unfractionated heparin (UFH) is limited by an inconvenient route of administration (continuous intravenous infusion) and a higher risk of heparin-induced thrombocytopenia and bleeding compared with low molecular weigh…

Adultmedicine.medical_specialtyBlood Loss SurgicalVenographyFondaparinuxRoute of administrationPharmacotherapymedicineHumansPharmacology (medical)DosingChildIntensive care medicineSocieties Medicalmedicine.diagnostic_testbusiness.industryAnticoagulantsVenous ThromboembolismHeparinmedicine.diseaseUnited StatesClinical trialVenous thrombosisClinical AlarmsPractice Guidelines as TopicDrug Monitoringbusinessmedicine.drugDrugs
researchProduct

Testing physiologic monitor alarm customization software to reduce alarm rates and improve nurses’ experience of alarms in a medical intensive care u…

2018

BACKGROUND:Clinicians in intensive care units experience alarm fatigue related to frequent false and non-actionable alarms produced by physiologic monitors. To reduce non-actionable alarms, alarm settings may need to be customized for individual patients; however, nurses may not customize alarms because of competing demands and alarm fatigue. OBJECTIVE:To examine the effectiveness and acceptance of physiologic monitor software to support customization of alarms. METHODS:This pre/post intervention study was conducted in a 56-bed medical intensive care unit. IntelliVue® Alarm Advisor customization support software for alarm limit violations was installed on all monitors and education on its u…

MaleTime FactorsPolymersHealth Care ProvidersRespiratory Tract Diseaseslcsh:MedicineNursesBlood PressureSurveysPathology and Laboratory Medicine01 natural sciencesVascular MedicinePersonalization0302 clinical medicineSoftwareHeart RateSoftware DesignMedicine and Health SciencesMedicine030212 general & internal medicineMedical Personnellcsh:SciencePolyvinyl ChlorideMaterialsFatigueMultidisciplinarySoftware EngineeringMiddle AgedHospitalsProfessionsIntensive Care UnitsChemistryMacromoleculesResearch DesignClinical AlarmsPhysical SciencesEngineering and TechnologyEquipment FailureFemaleMedical emergencyResearch ArticleComputer and Information SciencesMaterials ScienceCardiologyResearch and Analysis MethodsCommunicable DiseasesSoftware implementation03 medical and health sciencesALARMSigns and SymptomsRespiratory RateDiagnostic MedicineIntensive careHumansIn patientArterial PressureGlasgow Coma Scale0101 mathematicsAgedMonitoring PhysiologicSurvey Researchbusiness.industrylcsh:R010102 general mathematicsGlasgow Coma Scalemedicine.diseasePolymer ChemistryHealth CareMedical intensive care unitHealth Care FacilitiesPeople and Placeslcsh:QPopulation GroupingsbusinessSoftwarePLoS ONE
researchProduct

Ventilator Settings to Avoid Nuisance Alarms During Mouthpiece Ventilation

2016

BACKGROUND: A recent study found that activation of disconnection and low-pressure alarms is common during mouthpiece ventilation and may represent a major limitation to its use. The aim of this bench study was: (1) to investigate the technical aspects that can influence the setting of the ventilator during mouthpiece ventilation and (2) to provide a practical setting strategy to avoid the alarm activation. METHODS: Eight life-support ventilators able to deliver volume controlled ventilation were tested in a bench study using a single-limb non-vented circuit configuration connected to a standard mouthpiece. Disconnection and apnea alarm were turned off or set at the least sensitive setting.…

Pulmonary and Respiratory Medicinemedicine.medical_treatmentCritical Care and Intensive Care Medicine03 medical and health sciencesALARMMechanical ventilation0302 clinical medicineTidal VolumemedicineVentilator settingsHumansChronic respiratory failureChronic respiratory failure; Mechanical ventilation; Mechanical ventilators; Neuromuscular disease; Noninvasive ventilation; Pulmonary ventilation030212 general & internal medicineMouthpieceTidal volumeSimulationMechanical ventilationVentilators Mechanicalbusiness.industryApnea alarmMechanical ventilatorEquipment DesignGeneral MedicineNeuromuscular diseaseEquipment Failure AnalysisEquipment Failure Analysi030228 respiratory systemTurn offClinical AlarmsAnesthesiaPulmonary ventilationBreathingMechanical ventilatorsClinical AlarmbusinessNoninvasive ventilationHumanRespiratory Care
researchProduct

Incidence of potential drug interactions in a transplant centre setting and relevance of electronic alerts for clinical practice support

2013

Background Adverse drug events may occur as a result of drug–drug interactions (DDIs). Information technology (IT) systems can be an important decision-making tool for healthcare workers to identify DDIs.Objective The aim of the study is to analyse drug prescriptions in our main hospital units, in order to measure the incidence and severity of potential DDIs. The utility of clinical decision-support systems (CDSSs) and computerised physician order entry (CPOE) in term of alerts adherence was also assessed. DDIs were assessed using a Micromedex healthcare series database.Methods The system, adopted by the hospital, generates alerts for prescriptions with negative interactions and thanks to a…

computerised physicians order entrySafety Managementmedicine.medical_specialtymedicine.medical_treatmentHealth Informaticslcsh:Computer applications to medicine. Medical informaticsHospitals SpecialClinical decision support systemMedical Order Entry Systemslaw.inventionPatient safetyHealth Information ManagementlawHumansMedicineDrug Interactionsclinical decision-support systemMedical prescriptionIntensive care medicineDialysisRetrospective Studiesbusiness.industryIncidenceIncidence (epidemiology)Retrospective cohort studyOrgan TransplantationDecision Support Systems ClinicalIntensive care unitComputer Science ApplicationsClinical Alarmslcsh:R858-859.7businessAbdominal surgeryJournal of Innovation in Health Informatics
researchProduct

Telemonitoring in chronic pain management using smartphone apps: a randomized controlled trial comparing usual assessment against app-based monitorin…

2020

Background. The usefulness of mHealth in helping to target face-to-face interventions for chronic pain more effectively remains unclear. In the present study, we aim to test whether the Pain Monitor mobile phone application (app) is well accepted by clinicians, and can help improve existent medical treatments for patients with chronic musculoskeletal pain. Regarding this last goal, we compared three treatment conditions, namely usual treatment, usual treatment with an app without alarms and usual treatment with an app with alarms. All treatments lasted one month. The three treatments were compared for all outcomes, i.e., pain severity and interference, fatigue, depressed mood, anxiety and a…

medicine.medical_specialtyHealth Toxicology and Mutagenesismedia_common.quotation_subjectPsychological interventionlcsh:MedicineAngerArticlelaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawmental disordersmedicineHumansPain Management030212 general & internal medicinemHealthSalut mentalmedia_commonClinical eventsbusiness.industrylcsh:RPublic Health Environmental and Occupational HealthChronic painecological momentary assessmenttelemonitoringmedicine.diseaseMobile Applicationssmartphone appClinical AlarmsSmartphone apprandomized controlled trialPhysical therapyAnxietySmartphonemedicine.symptomChronic Painbusinesschronic pain030217 neurology & neurosurgery
researchProduct